not-heating [2018/06/21 11:20] โ€“ samuelpinchesnot-heating [2019/02/18 20:52] โ€“ samuelpinches
Line 18: Line 18:
  
 If you see an error about "HEATING FAILED" this means that the printer did not detect a sufficient change in temperature while heating up. This is a safety feature, and suggests there is a fault with wiring somewhere - energy is going in, but it is not ending up in the bed. Perhaps there is a loose connection somewhere - for example the heated bed connector may be damaged. If you see an error about "HEATING FAILED" this means that the printer did not detect a sufficient change in temperature while heating up. This is a safety feature, and suggests there is a fault with wiring somewhere - energy is going in, but it is not ending up in the bed. Perhaps there is a loose connection somewhere - for example the heated bed connector may be damaged.
 +
 +For more info on the thermal safety systems in the Marlin Firmware, see [[thermal-runaway|this page]].
  
 ==== 3. Check your sensors and heaters are not broken ===== ==== 3. Check your sensors and heaters are not broken =====
Line 25: Line 27:
 A video tutorial on replacing the Hot-End Thermistor can be found [[https://youtu.be/eDtfU_w1hA8|here]]. A video tutorial on replacing the Hot-End Thermistor can be found [[https://youtu.be/eDtfU_w1hA8|here]].
  
-**If you think your motherboard thermistor port is damaged, there is more information on using the spare port [[a5:faulty-temperature-readings|here]].**+==== Further Troubleshooting ====ย 
 +**If you are still getting faulty temperature readings after checking your thermistor temperature sensors are ok, it may be that your motherboard thermistor sensor port is damaged. There is information on using the spare port [[a5:faulty-temperature-readings|here]].**
  
 {{page>template-sections#still stuck}} {{page>template-sections#still stuck}}