a5:programmable-power-supply-control
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
a5:programmable-power-supply-control [2018/07/05 21:37] โ [Use New Functions] aeket | a5:programmable-power-supply-control [2020/12/25 02:13] (current) โ external edit 127.0.0.1 | ||
---|---|---|---|
Line 4: | Line 4: | ||
The changes shown here require knowledge in the field of Arduino, Marlin firmware and electrical engineering and can overwhelm normal users. Also, I would like to point out possible dangers that exist in certain interventions. All adjustments have been checked for function. | The changes shown here require knowledge in the field of Arduino, Marlin firmware and electrical engineering and can overwhelm normal users. Also, I would like to point out possible dangers that exist in certain interventions. All adjustments have been checked for function. | ||
- | **Difficulty: | + | **Difficulty: |
**What is this about?** \\ | **What is this about?** \\ | ||
Line 63: | Line 63: | ||
==== Customize the Marlin firmware ==== | ==== Customize the Marlin firmware ==== | ||
- | In the Arduino IDE open the **A5 Custom Community Firmware** (see article here in WIKI).\\ | + | In the Arduino IDE open the **A5 Custom Community Firmware** (see [[a5: |
__ | __ | ||
The following adjustments are made in the " | The following adjustments are made in the " | ||
Line 145: | Line 145: | ||
I had developed a complex special housing for the momentary switch and the solid state relay, in which the circuit should find its place. This would look like this: | I had developed a complex special housing for the momentary switch and the solid state relay, in which the circuit should find its place. This would look like this: | ||
+ | |||
{{: | {{: | ||
+ | |||
Electrically everything worked wonderfully. Unfortunately I noticed a problem after assembling the A5. The measurement of the available space above the momentary switch upper edge was wrong. The Y-gantry does not have enough room to move because the housing of the momentary switch was too high.\\ | Electrically everything worked wonderfully. Unfortunately I noticed a problem after assembling the A5. The measurement of the available space above the momentary switch upper edge was wrong. The Y-gantry does not have enough room to move because the housing of the momentary switch was too high.\\ | ||
\\ | \\ | ||
Line 181: | Line 183: | ||
AETEK Firmware:\\ | AETEK Firmware:\\ | ||
{{: | {{: | ||
- | \\ | + | {{: |
After the successful update of the MKS display firmware it should now look like this:\\ | After the successful update of the MKS display firmware it should now look like this:\\ | ||
Line 218: | Line 220: | ||
=== Operation via software (GCODES) === | === Operation via software (GCODES) === | ||
- | GCODES can be sent directly to the A5 via USB, e.g. Pronterface. \\ | + | GCODES can be sent directly to the A5 via USB, e.g. [[: |
There is also the option to send stored GCODES from a storage device, such as USB stick or SD card. \\ | There is also the option to send stored GCODES from a storage device, such as USB stick or SD card. \\ | ||
Which GCODES are of interest for this project?\\ | Which GCODES are of interest for this project?\\ |
a5/programmable-power-supply-control.1530790672.txt.gz ยท Last modified: 2020/12/25 02:13 (external edit)